GM Service Manual Online
For 1990-2009 cars only

Removal Procedure

  1. Remove the HVAC module assembly. Refer to HVAC Module Assembly Replacement .
  2. Remove the screws that secure the recirculation housing to the HVAC module assembly.

  3. Object Number: 1263138  Size: SH
  4. Remove the recirculation housing from the HVAC module assembly.
  5. Remove the screws that secure the mode actuator to the HVAC module assembly.
  6. Remove the mode actuator from the HVAC module assembly.
  7. Remove the screws that secure HVAC module assembly upper case to the HVAC module assembly lower case.
  8. Remove the heat stakes that secure the HVAC module assembly upper case to the HVAC module lower case using a small chisel.

  9. Object Number: 295357  Size: SH
  10. Separate the HVAC module assembly case (1).
  11. Remove the screws that secure the air temperature actuator to the HVAC module assembly upper case.
  12. Remove the air temperature actuator from the HVAC module assembly upper case.

  13. Object Number: 1194914  Size: SH
  14. Remove the air temperature door from the HVAC module assembly upper case.
  15. Remove the left air temperature door from the air temperature door assembly.

Installation Procedure

  1. Install the left air temperature door to the air temperature door assembly.

  2. Object Number: 1194914  Size: SH
  3. Install the air temperature door to the HVAC module assembly upper case.
  4. Install the air temperature actuator to the HVAC module assembly upper case.
  5. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  6. Install the screws that secure the air temperature actuator to the HVAC module assembly upper case.
  7. Tighten
    Tighten the screws to 1.5 N·m (13 lb in).

  8. From the inside of the upper case, drill the dimples adjacent to the heat stakes using a 5.5 mm (7/32 in) drill bit.

  9. Object Number: 295357  Size: SH
  10. Align and attach the upper and lower HVAC module assembly case.
  11. Install the removed screws that secure the HVAC module assembly upper case to the HVAC module assembly lower case to their original position.
  12. Tighten
    Tighten the screws to 1.5 N·m (13 lb in).

  13. Install new screws that will secure the HVAC module assembly upper case to the HVAC module assembly lower case in the locations adjacent to the heat stakes.
  14. Tighten
    Tighten the screws to 1.5 N·m (13 lb in).

  15. Install the mode actuator.
  16. Install the screws that secure the mode actuator to the HVAC module assembly.
  17. Tighten
    Tighten the screws to 1.5 N·m (13 lb in).


    Object Number: 1263138  Size: SH
  18. Install the recirculation housing to the HVAC module assembly.
  19. Install the screws that secure the recirculation housing to the HVAC module assembly.
  20. Tighten
    Tighten the screws to 1.5 N·m (13 lb in).

  21. Install the HVAC module assembly. Refer to HVAC Module Assembly Replacement .