GM Service Manual Online
For 1990-2009 cars only

Step

Action

Value(s)

Yes

No

1

Did you perform the HVAC Blower Controls System Check?

--

Go to Step 2

Go to HVAC Blower Controls System Check

2

  1. Turn the ignition switch to the RUN position.
  2. Use the J 39200 .

Does the voltage measured equal the specified value?

B+

Go to Step 3

Go to Step 4

3

  1. Disconnect the heater A/C control assembly connector C2.
  2. Use the J 39200 .

Does the voltage measured equal the specified value?

B+

Go to Step 5

Go to Step 6

4

Use the J 39200 .

Does the voltage measured equal the specified value?

B+

Go to Step 7

Go to Step 8

5

  1. Reconnect the heater A/C control assembly connector C2.
  2. Use the J 39200 .
  3. Measure the voltage between terminal G and ground.
  4. Turn the temperature control from COLD to HOT.

Does the voltage vary within the specified range?

1-12 V

Go to Step 9

Go to Step 10

6

Repair the open in CKT 251 between the heater A/C control assembly and ground splice pack G204. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to HVAC Blower Controls System Check

--

7

Repair the open in CKT 41 between the underhood wiring harness junction block and the heater A/C control assembly. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to HVAC Blower Controls System Check

--

8

Replace the underhood wiring harness junction block. Refer to Relay/Fuse Center Replacement .

Is the repair complete?

--

Go to HVAC Blower Controls System Check

--

9

  1. Disconnect the air temperature actuator connector.
  2. Connect the J 39200 .
  3. Turn the temperature control from COLD to HOT.

Does the voltage vary within the specified range?

1-12 V

Go to Step 11

Go to Step 12

10

Replace the heater A/C control assembly. Refer to Control Assembly Replacement .

Is the repair complete?

--

Go to HVAC Blower Controls System Check

--

11

Connect the J 39200 .

Does the voltage measured equal the specified value?

B+

Go to Step 13

Go to Step 14

12

Repair the open in CKT 733 between the air temperature actuator and the heater A/C control assembly. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to HVAC Blower Controls System Check

--

13

Use the J 39200 .

Does the voltage measured equal the specified value?

B+

Go to Step 15

Go to Step 16

14

Repair the open in CKT 41 between the underhood wiring harness junction block and the air temperature actuator. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to HVAC Blower Controls System Check

--

15

Replace the air temperature actuator.

Is the repair complete?

--

Go to HVAC Blower Controls System Check

--

16

Repair the open in CKT 251 between the air temperature actuator and ground splice pack G204. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to HVAC Blower Controls System Check

--