GM Service Manual Online
For 1990-2009 cars only

Circuit Description

The instrument panel integration module (IPM) commands right air temperature actuator movement with one of three voltage signals applied to the right air temperature door control circuit. A low voltage of 0 volts moves the right air temperature door toward full hot, 2.5 volts stops the actuator, and 5 volts moves the right air temperature door toward full cold. The IPM determines the current position of the actuator by monitoring the feedback voltage of the right air temperature door position signal circuit. The feedback potentiometer position is a function of the actuator position. A high voltage indicates a full cold right air temperature door position. A low voltage indicates a full hot right air temperature door position. The IPM controls the right air temperature door position in order to maintain the selected air temperature on the HVAC control module.

Whenever the IPMs keep alive memory battery power is interrupted, the IPM will perform a recalibration of the actuators. During recalibration, the IPM will drive the actuators to their minimum and maximum travel extremes. The IPM will then calculate a travel range from this data (max-min=range) and compare it to a calibrated range within the IPM. If the actual travel range is not within the calibrated expected range, the actuator will be considered not calibrated and the DTC will set.

Conditions for Running the DTC

    • The ignition is turned ON.
    • The IPM power must be interrupted.
    •  Perform the Recalibrate all Motors command using the scan tool.

Conditions for Setting the DTC

The right air temperature actuator actual total travel range (max-min) is less than or greater than the calibrated limits.

Action Taken When the DTC Sets

    • The IPM will continue to make use of whatever right air temperature actuator travel range is still available.
    • Each time the ignition switch is turned ON the IPM will perform a recalibration of the actuator.

Conditions for Clearing the DTC

The right air temperature actuator travel range error must be corrected.

Diagnostic Aids

    • The range fault code can only be detected following a check of the right air temperature actuator travel range. The right air temperature actuator travel range check can only be initiated by disrupting power to the IPM (disconnecting the battery) or with the scan tool.
    • The calibration limit is 147-220 counts (2.9-4.4 V). An actual range below this limit suggests an obstruction (something stuck in the door limiting travel). An actual range above this limit suggests an over travel condition (damaged or missing foam seals).
    • If the condition is not present, refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.

Step

Action

Values

Yes

No

Schematic Reference: HVAC Schematics

1

Did you perform the HVAC Diagnostic System Check?

--

Go to Step 2

Go to Diagnostic System Check - HVAC Systems - Automatic

2

  1. Install a scan tool.
  2. Turn ON the ignition, with the engine OFF.
  3. With a scan tool, observe the Min Right Temp Dr Pos and the Max Right Temp Dr Pos parameters in the Instrument Panel Module HVAC Doors Calibrations data list.
  4. Subtract the Min Right Temp Dr Pos from the Max Right Temp Dr Pos.

Does the result of the calculation indicate that the actual travel of the right air temperature actuator is within the specific range?

147-220 counts

Go to Diagnostic Aids

Go to Step 3

3

Test the ignition 3 voltage circuit of the right air temperature actuator for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 13

Go to Step 4

4

Test the door control circuit of the right air temperature actuator for an open, high resistance, short to ground or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 13

Go to Step 5

5

Test the 5-volt reference circuit of the right air temperature actuator for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 13

Go to Step 6

6

Important: Ensure that the right air temperature actuator connector and the instrument panel integration module connector are connected during this step in order to avoid misdiagnosis.

  1. Turn ON the ignition, with the engine OFF.
  2. With the scan tool, observe the Right Temp Dr Actual data parameter in the Instrument Panel Module HVAC Door Positions data list.
  3. Connect a 3-amp fused jumper wire between the door control circuit and the 5-volt reference circuit of the right air temperature actuator (drives the actuator full COOL).
  4. Remove and reconnect the jumper wire between the door control circuit and the low reference circuit of the right air temperature actuator (drives the actuator full HOT).

Does the right air temperature actuator drive shaft rotate and do the counts change?

--

Go to Step 7

Go to Step 9

7

  1. Measure the voltage from the door control circuit of the right air temperature actuator to a good ground.
  2. With a scan tool, command the Right Temp Door Position from Hot to Cold.

Does the voltage measure near the specified value when increasing temperature, near the specified value when decreasing temperature and near the specified value when stationary?

0 V increasing

5 V decreasing

2.5 V stationary

Go to Step 8

Go to Step 10

8

Inspect the right air temperature door and the right air temperature actuator for the following conditions.

    • A misaligned air temperature actuator. Refer to Air Temperature Actuator Replacement - Right Side .
    • Broken or binding linkages or air temperature door
    • An obstruction that prevents the air temperature actuator from operating within it's full range of motion
    • Missing seals to the air temperature door
    • Misaligned seals to the air temperature door

Did you find and correct the condition?

 

Go to Step 13

Go to Diagnostic Aids

9

Inspect for poor connections at the harness connector of the right air temperature actuator. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 13

Go to Step 11

10

Inspect for poor connections at the harness connector of the instrument panel integration module (IPM). Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 13

Go to Step 12

11

Important: : Perform the Recalibration procedure for the right air temperature actuator.

Replace the right air temperature actuator. Refer to Air Temperature Actuator Replacement - Right Side .

Did you complete the replacement?

--

Go to Step 13

--

12

Important: : Perform the Recalibration procedure for the instrument panel integration module.

Replace the instrument panel integration module. Refer to Instrument Panel Module Replacement in Body Control System.

Did you complete the replacement?

--

Go to Step 13

--

13

  1. Use the scan tool in order to clear the DTCs.
  2. Operate the vehicle within the Conditions for Running the DTC as specified in the supporting text.

Does the DTC reset?

--

Go to Step 2

System OK