DTC Descriptor

DTC B3445: Stop Lamp Circuit

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

Center High Mounted Stop Lamp (CHMSL) Control

B3445

1

1

--

CHMSL Ground

--

1

--

--

1. Stop Lamps Malfunction

Circuit/System Description

The brake pedal position sensor is used to sense the action of the driver application of the brake pedal. The brake pedal position sensor provides an analog voltage signal that will increase as the brake pedal is applied. The body control module (BCM) provides a low reference signal and a 5-volt reference voltage to the brake pedal position sensor. When the variable signal reaches a voltage threshold indicating the brakes have been applied, the BCM will apply battery voltage to the right and left stop lamp control circuits, transmission control module (TCM), electronic brake control module (EBCM), engine control module (ECM), and center high mounted stop lamp (CHMSL) control circuit.

Conditions for Running the DTC

    • Battery voltage must be between 9-16 volts.
    • Brakes APPLIED.

Conditions for Setting the DTC

DTC B3445 will set when the BCM detects a short to ground in the CHMSL control circuit when the stop lamps are being commanded ON.

Action Taken When the DTC Sets

The BCM will not illuminate the CHMSL.

Conditions for Clearing the DTC

    • The condition responsible for setting the DTC no longer exists.
    • A history DTC will clear once 100 consecutive malfunction-free ignition cycles have occurred.

Diagnostic Aids

Important: The stop lamps will not illuminate unless the ignition is in the ON position. For more detailed information concerning stop lamp operation, refer to Exterior Lighting Systems Description and Operation .

Reference Information

Schematic Reference

Exterior Lights Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Exterior Lighting Systems Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector at the CHMSL.
  2. Ignition OFF, test for less than 5.0 ohms between the ground circuit terminal B and ground.
  3. If greater than the specified range, test the ground circuit for an open/high resistance.
  4. Connect a test lamp between the control circuit terminal A and the ground circuit terminal B.
  5. Ignition ON, command the stop lamps ON and OFF by applying and releasing the brake pedal. The test lamp should turn ON and OFF when changing between the commanded states.
  6. If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM.
    If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM.
  7. If all circuits test normal, replace the CHMSL.