GM Service Manual Online
For 1990-2009 cars only
Table 1: DTC B1071 Internal SDM Failure

Circuit Description

DTC B1071 is an indication of a potential internal inflatable restraint sensing and diagnostic module (SDM) malfunction. DTC B1071 will set upon the detection of any condition in the table below.

Conditions for Setting the DTC

Malfunction

Detection Test

23 VLR voltage out of normal operating range.

Power-On, Continuous monitoring

Crash data recording reserve voltage discharge time failure for 3 consecutive ignition cycles.

Power On

The calculated checksum for internal memory does not match the stored value.

Power On

The driver or passenger deployment loop is shorted to ground.

Continuous monitoring

The Accelerometer is malfunctioning.

Power On, Continuous monitoring

The driver or passenger current source is malfunctioning.

Resistance measurement

The temporary memory storage area is malfunctioning.

Power On

The inflatable restraint Sensing and Diagnostic Module (SDM) is unable to read from or write to EEPROM.

Power On

The arming sensor inside the Inflatable Restraint Sensing and Diagnostic Module (SDM) is not closed during a deployment event.

Asynchronously

The voltage measured at the DRIVER LOW and the PASSENGER LOW is too low.

Power On, Continuous monitoring

The device inside the inflatable restraint sensing and diagnostic module that arms the system for deployment is malfunctioning.

Power On, Continuous monitoring

The permanent memory storage area is malfunctioning.

Power On

Action Taken When the DTC Sets

    • The SDM sets a diagnostic trouble code.
    • The SDM turns ON the AIR BAG Warning Indicator.

Conditions for Clearing the MIL/DTC

    • Current DTC
        The malfunction has not been detected for 500 milliseconds.
    • History DTC
       - You issue a scan tool CLEAR CODES command.
       - 250 malfunction free ignition cycles have occurred.

Diagnostic Aids

When you issue a scan tool CLEAR CODES command, some of the indicated malfunctions will only allow the AIR BAG warning lamp to turn off briefly, then turn back ON.

DTC B1071 Internal SDM Failure

Step

Action

Value(s)

Yes

No

Notice: When DTC B1018 or B1024 has been set it is necessary to replace the inflatable restraint Sensing and Diagnostic Module (SDM). Setting DTC B1018 or B1024 will also cause DTC B1071 to set. When a scan tool clear codes command is issued and the malfunction is no longer present, DTC B1018 or B1024 and DTC B1071 will remain current. Make sure that the short to ground condition is repaired prior to installing a replacement SDM to avoid damaging the SDM.

1

Did you preform the SIR Diagnostic System Check?

--

Go to Step 2

Go to SIR Diagnostic System Check

2

Is DTC B1018 set?

--

Go to DTC B1018 Passenger Deployment Loop Short to GND

Go to Step 3

3

Is DTC B1024 set?

--

Go to DTC B1024 Driver Deployment Loop Short to Ground

Go to Step 4

4

  1. Turn the ignition switch OFF.
  2. Replace the inflatable restraint Sensing and Diagnostic Module (SDM). Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement .

Is the repair complete?

--

Go to SIR Diagnostic System Check

--