Removal Procedure

  1. Remove the air cleaner element. Refer to Air Cleaner Element Replacement .

  2. Object Number: 732051  Size: SH
  3. Disconnect the electrical connector from the intake air temperature (IAT) sensor (1).
  4. Loosen the air cleaner outlet duct clamp (2) on the air cleaner side of the air cleaner outlet resonator (3).
  5. Remove the air cleaner outlet duct.
  6. If replacing the air cleaner outlet duct, remove the IAT sensor. Refer to Intake Air Temperature Sensor Replacement .

Installation Procedure

  1. If the IAT sensor was previously removed, install the IAT sensor into the air cleaner outlet duct. Refer to Intake Air Temperature Sensor Replacement .

  2. Object Number: 732051  Size: SH
  3. Install the air cleaner outlet duct onto the air cleaner outlet resonator (3).
  4. Install the air cleaner element. Refer to Air Cleaner Element Replacement .
  5. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  6. Properly position the air cleaner outlet duct clamp (2) on the air cleaner side of the air cleaner outlet resonator (3).
  7. Tighten
    Tighten the clamp (2) to 4 N·m (35 lb in).

  8. Connect the electrical connector to the IAT sensor (1).